User Tools

Site Tools


samples:t8

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
samples:t8 [2015/05/28 09:39]
taylorcd created
samples:t8 [2015/07/21 13:25] (current)
sgneitin
Line 2: Line 2:
  
 ==Purpose== ==Purpose==
-This sample as two sets of 6 transducers. Each set is comprised of three transducers toward the edge and three transducers away from the edge.  One set is pointing ​towards ​each other, while the other points ​away.  These are designed to see the interactions of SAW waves with two transducers in the light path.+This sample as two sets of 6 transducers. Each set is comprised of three transducers toward the edge and three transducers away from the edge.  One set is pointing ​away from each other (Set 1), while the other points ​towards each other (Set 2).  These are designed to see the interactions of SAW waves with two transducers in the light path.
 ==Past:== ==Past:==
- To be written by Jacob.+ Y-cut Lithium Niobate. ​ Normal prep, no proton exchange.
  
 Only minor flaws in the transducers are visible. ​ Only minor flaws in the transducers are visible. ​
  
 Sign Sign
-{{::​t8_sign.jpg?​100|}}+{{:samples:t:​t8_sign.jpg?​100|}}
 ==Set 1 (pointing away from each other)== ==Set 1 (pointing away from each other)==
 Near the edge Near the edge
-{{::​t8_outside_pointed-out.jpg?​100|}}+{{:samples:t:​t8_outside_pointed-out.jpg?​100|}}
 Away from the edge Away from the edge
-{{::​t8_inside_pointed-in.jpg?​100|}}+{{:samples:t:​t8_inside_pointed-in.jpg?​100|}}
 ==Set 2 (pointing towards each other)== ==Set 2 (pointing towards each other)==
 Near the edge Near the edge
-{{::t8_outside_pointed-in.jpg?​100|}}+{{:samples:t:​outside_pointed-in.jpg?​100|}}
 Away from the edge Away from the edge
-{{::​t8_inside_pointed-out.jpg?​100|}}+{{:samples:t:​t8_inside_pointed-out.jpg?​100|}} 
 + 
 + 
 +Wire Bonded as follows: 
 +{{:​samples:​t:​2015-06-01_17.07.26.jpg}} 
 + 
 +When referring to numbered transducers, ​ it is understood that one is the transducer connected to that number port. 
 + 
 +Most of the transducers are well connected, and match each other well.   They were fabricated well.  Transduers 1, 9, and 10 were open on 6-1-15, but the next day Transducer 1 was functioning and t9 and 10 were closed when inductors were placed, however all other transducers are extremely similar. ​ Each has some smith chart disturbances and a very slight dip in the SWR chart between 150-200 MHz and all have a major loop around 600-700 MHz.   
 +Smith Charts and SWR for each port **Before Impedance Matching** (As counted from the top): 
 + 
 +^            T1               ​^ ​           T2               ​^ ​           T3               ^ 
 +|  {{:​samples:​t:​t8t1smithreal.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t2smith.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t3smith.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t1swrreal.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t2swr.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t3swr.jpg?​200|}} ​  | 
 +^            T4               ​^ ​           T5               ​^ ​           T6               ^ 
 +|  {{:​samples:​t:​t8t4smith.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t5smith.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t6smith.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t4swr.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t5swr.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t6swr.jpg?​200|}} ​  | 
 +^            T7               ​^ ​           T8               ​^ ​           T9               ^ 
 +|  {{:​samples:​t:​t8t7smith.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t8smith.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t9smith.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t7swr.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t8swr.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t9swr.jpg?​200|}} ​  | 
 +^            T10               ​^ ​           GND1               ​^ ​           GND2               ^ 
 +|  {{:​samples:​t:​t8t10smith.jpg?​200|}} ​  | Between T3 and T4  |  Between T7 and T8 | 
 +|  {{:​samples:​t:​t8t10swr.jpg?​200|}} ​  ​| ​   |     | 
 + 
 +Smith and Swr charts after impedance matching. ​ Note that the loops in the lower frequencies (to which I impedance matched) were not as "​pretty"​ as the big loops in the upper frequencies. 
 +Two inductances were used, 100 nH and 82 nH. 
 + 
 +^Inductance^ ​      82 nH       ​^ ​      100 nH       ^ 
 +|Transducer number| 3, 4, 6, 8 |  1, 2, 5, 7, 9, 10 | 
 + 
 +^            T1               ​^ ​           T2               ​^ ​           T3               ^ 
 +|  {{:​samples:​t:​t8t1smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t2smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t3smithm.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t1swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t2swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t3swrm.jpg?​200|}} ​  | 
 +^            T4               ​^ ​           T5               ​^ ​           T6               ^ 
 +|  {{:​samples:​t:​t8t4smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t5smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t6smithm.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t4swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t5swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t6swrm.jpg?​200|}} ​  | 
 +^            T7               ​^ ​           T8               ​^ ​           T9               ^ 
 +|  {{:​samples:​t:​t8t7smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t8smithm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t9smithm.jpg?​200|}} ​  | 
 +|  {{:​samples:​t:​t8t7swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t8swrm.jpg?​200|}} ​  ​| ​ {{:​samples:​t:​t8t9swrm.jpg?​200|}} ​  | 
 +^            T10               ​^ ​           GND1               ​^ ​           GND2               ^ 
 +|  {{:​samples:​t:​t8t10smithm.jpg?​200|}} ​  | Between T3 and T4  |  Between T7 and T8 | 
 +|  {{:​samples:​t:​t8t10swrm.jpg?​200|}} ​  ​| ​   |     |
  
samples/t8.1432827577.txt.gz · Last modified: 2015/05/28 09:39 by taylorcd