====A10==== ==Past:== Used SiO2 mask to create channels and 1.4mm non-proton exchanged region. Proton exchanged 10min, annealed 45min. ==Current:== prepped with LOR and pmma for writing. Written, evaporated, lifted off. Success! (There is overlap between transducers and waveguide) {{:samples:a:a10_liftoff_full.jpg?direct&100|}} {{:samples:a:a10_liftoff_left.jpg?direct&100|}} {{:samples:a:a10_liftoff_right.jpg?direct&100|}} This device showed only one mode on the Metricon. We will try re-annealing the device for 30 minutes to see if we can create a second mode. The device was successfully annealed for 30 minutes. ^ Before Anneal ^ After Anneal ^ | {{:samples:a:a10_scrn.jpg?300|}} | {{:samples:a:a10_metricon_after_aneal.jpg?300|}} | The Metricon still only detects one mode. ==Red== {{:samples:a:aom-a10-red-6.18.2015-10.23am-graph.jpeg?800|}} ==Green== {{:samples:a:aom-a10-green-6.18.2015-10.37am-graph.jpeg?800|}} ==Blue== {{:samples:a:aom-a10-blue-6.18.2015-3.39pm-graph.jpeg?800|}} The bump arround 310MHz is an anomaly caused by the interaction between scattered light and the transducers. I have video evidence of this fact. The humps around 550 MHz are the true humps. The same goes for the bump around -40°. ==Comparison results== {{:samples:a:sample_a10_t10_comparison_data.jpeg?800|}} ==Future:== given to Scott for polishing and testing. ---- Sample fabricated by Jacob Kimball\\ page updated 4 June 2015