====A5==== ==Past:== Used Al mask to create channels and 2.4mm non-proton exchanged region. Proton exchanged 10min, annealed 45min. ==Current:== Written, evaporated, lifted off. Success! {{:samples:a:a5_liftoff_full.jpg?direct&100|}} {{:samples:a:a5_liftoff_left.jpg?direct&100|}} {{:samples:a:a5_liftoff_right.jpg?direct&100|}} Metricon: {{:samples:a:a5_scrn.jpg?200}} System Analyzer Preliminary testing on six transducers. (T1, T4, T6, T11, T15, T18) Non-uniform order due to limited space on certain transducer bonding pads. 27 nH used with each transducer. ^ T1 ^ T4 ^ T6 ^ | {{:samples:a:a5t1smith.jpg?200|}} | {{:samples:a:a5t4smith.jpg?200|}} | {{:samples:a:a5t6smith.jpg?200|}} | | {{:samples:a:a5t1swr.jpg?200|}} | {{:samples:a:a5t4swr.jpg?200|}} | {{:samples:a:a5t6swr.jpg?200|}} | ^ T11 ^ T15 ^ T18 ^ | {{:samples:a:a5t11smith.jpg?200|}} | {{:samples:a:a5t15smith.jpg?200|}} | {{:samples:a:a5t18smith.jpg?200|}} | | {{:samples:a:a5t11swr.jpg?200|}} | {{:samples:a:a5t15swr.jpg?200|}} | {{:samples:a:a5t18swr.jpg?200|}} | ==Red== {{:samples:a:aom-a5-red-6.18.2015-5.05pm-graph.jpeg?800|}} ==Green== {{:samples:a:aom-a5-green-6.18.2015-5.14pm-graph.jpeg?800|}} ==Blue== {{:samples:a:aom-a5-blue-6.18.2015-5.31pm-graph.jpeg?800|}} ==Comparison Data== {{:samples:a:sample_a5_t11_comparison_data.jpeg?800|}} ==Future:== Testing by Scott ---- Sample fabricated by Jacob Kimball\\ page updated 10 June 2015