====D7==== ==Past:== D7 was proton exchanged for 10 minutes and annealed for 45 minutes. Prepped with pmma and aqua save for ESEM. Written in ESEM at Spot 5 for long transducers, developed for 1 minute. Evaporated 200nm Aluminum, placed in NMP for liftoff. Liftoff successful for all but one Low Frequency device. The outside Low F device shorted. Sign {{:samples:d:d7_sign.jpg?100|}} Low F {{:samples:d:d7lowf.jpg?100|}} Mid F {{:samples:d:d7midf.jpg?100|}} High F {{:samples:d:d7highf.jpg?100|}} Smith Charts and SWR for each port **Before Impedance Matching** (As counted from the top): ^ T1 ^ T2 ^ T3 ^ | {{:samples:d:d9_006.jpg?200|}} | {{:samples:d:d9_010.jpg?200|}} | {{:samples:d:d9_014.jpg?200|}} | | {{:samples:d:d9_008.jpg?200|}} | {{:samples:d:d9_012.jpg?200|}} | {{:samples:d:d9_016.jpg?200|}} | | T4 | T5 | T6 | | {{:samples:d:d9_018.jpg?200|}} | {{:samples:d:d9_022.jpg?200|}} | {{:samples:d:d9_026.jpg?200|}} | | {{:samples:d:d9_020.jpg?200|}} | {{:samples:d:d9_024.jpg?200|}} | {{:samples:d:d9_028.jpg?200|}} | Smith Charts and SWR for each port **After Impedance Matching** (As counted from the top): ^ T5 ^ T6 ^ | {{:samples:d:d7_002.jpg?200|}} | {{:samples:d:d7_006.jpg?200|}} | | {{:samples:d:d7_004.jpg?200|}} | {{:samples:d:d7_008.jpg?200|}} | A three bounce light guided test was successful with the green laser. The parameters were as follows: 5.4V, T6, a 7 MHz bandwidth centered at 673 MHz with a deflection of about 2 degrees. The positioning angle read 5 degrees. A video was captured and stored on my machine. ==Current:== Handed off to Scott for wirebonding and testing. ==Future:== ?? ---- Sample fabricated by Jacob Kimball\\ page updated 14 May 2015