To use the intermetallic crucibles, you must go through specialized instruction with Stephen or one of his representatives (If you don't know if you are one, then you're not).
Aluminum:
* Set the beam to the center of both Lateral and Longitudinal markers
* This can be done by setting the beam to manual and moving the joystick to the center of its range
* See picture for “Center”
* Do not let the beam touch the edges of the crucible (Think plagues of Egypt sort of bad)
* Set the Lateral and Longitudinal frequency to 200 and the amplitude to 200.
* This is done by setting the “Hundreds” number (the one on the top edge of the nob) to 2, and the “Tens” (the numbers on the dial itself) to 00.
* See picture below for location of frequency and amplitude nobs
* If you've centered the beam and set the frequency, then all you have to do is keep the deposition rate steady until you reach your target.
Germanium
Nichrome:
Chrome