User Tools

Site Tools


samples:t9

T9

Purpose

This sample as two sets of 6 transducers. Each set is comprised of three transducers toward the edge and three transducers away from the edge. One set is pointing away from each other (Set 1), while the other points towards each other (Set 2). These are designed to see the interactions of SAW waves with two transducers in the light path.

Past:

Y-cut Lithium Niobate. Normal prep, no proton exchange.

Only minor flaws in the transducers are visible.

Sign

Set 1 (pointing away from each other)

Near the edge Away from the edge

Set 2 (pointing towards each other)

Near the edge Away from the edge

Wire Bonded as follows: 2015-06-05_09.37.18.jpg

Smith and SWR charts before impedance matching. It is noted that very few of the transducers are functioning. Specifically only T4,T6,T7,T8, and T10. Unsure as to why.

T1 T2 T3
T4 T5 T6
T7 T8 T9
T10 GND1 GND2
Between T3 and T4 After 10

After Impedance matching

T1 T2 T3
T4 T5 T6
T7 T8 T9
T10 GND1 GND2
Between T3 and T4 After 10
samples/t9.txt · Last modified: 2015/07/21 13:24 by sgneitin